Supplied and delivered by Audimat, official Italvibras distributor : three-phase 8-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.
ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22
Availability
At 9,04 kN and 750 rpm, the CDX 075/1310-G/D occupies size 60 in the CDX range. Its spheroidal graphite cast iron frame and flameproof joints let it work inside a potentially explosive atmosphere.
Like every size from 40 upwards, it is relubricated through two greasing channels closed by screw plugs. Audimat, official Italvibras distributor.
| Centrifugal force (100 %, 50 Hz) | 9,04 kN |
| Centrifugal force (100 %, 60 Hz) | 13,00 kN |
| Speed (50 Hz) | 750 rpm |
| Static moment (50 Hz) | 1464 kgmm |
| Rated power (50 Hz) | 480 W |
| Max. power input (50 Hz) | 750 W |
| Max. current (400 V / 50 Hz) | 1,52 A |
| Weight | 109 kg |
| Dimensions L×W×H | 634 × 275 × 312 mm |
| Frame size | 60 |
| Cable gland | NPT 3/4″, no cable gland |
| ATEX certification | II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db |
| Permitted zones | 1, 2, 21 and 22 |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Item code | 602555 |
| Brand | Italvibras |
Overall dimensions from the Italvibras catalogue (A × C × B).
Documents to download
Documentation reserved for Audimat customers — request the access code.
Particularly suited to the following applications :
The CDX 075/1310-G/D houses a three-phase asynchronous motor whose enclosure applies the flameproof protection method « db »: the thickness of the frame and the geometry of the flameproof joints stop an internal explosion from spreading to the surrounding atmosphere. Protection IP66, impact resistance IK08, insulation class F (155 °C), continuous operation from −20 °C to +40 °C.
Its centrifugal force adjusts steplessly from 0 to 100 % through the eccentric weights, with the patented ARS system preventing setting errors. Thermal protection 130 °C is fitted as standard, as on every type G/D CDX, and connecting it is an integral part of the conditions of use in a classified zone.
CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.
A question about sizing, zone classification or compatibility with your installation ? get in touch.