Supplied and delivered by Audimat, official Italvibras distributor : three-phase 6-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas atmospheres.
ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1 & 2
Availability
The CDX 10/22000-G is size 110 of the Italvibras flameproof series in 6 poles. At 1’000 rpm it delivers 220 kN on 50 Hz, with a spheroidal graphite cast iron frame and an extra-thick terminal box cover sized to contain an internal explosion.
This is the largest frame in the series, a machine of over a tonne reserved for the heaviest structures. Audimat, official Italvibras distributor.
| Centrifugal force (100 %, 50 Hz) | 220 kN |
| Centrifugal force (100 %, 60 Hz) | 198 kN |
| Speed (50 Hz) | 1’000 rpm |
| Static moment (50 Hz) | 20025 kgmm |
| Rated power (50 Hz) | 11800 W |
| Max. power input (50 Hz) | 15600 W |
| Max. current (400 V / 50 Hz) | 25,2 A |
| Weight | 928 kg |
| Dimensions L×W×H | 1150 × 610 × 614 mm |
| Frame size | 110 |
| Cable gland | NPT 1″, no cable gland |
| ATEX certification | II 2 G Ex db IIB 160 °C Gb |
| Permitted zones | 1 and 2 (gas atmospheres) |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Item code | 602201 |
| Brand | Italvibras |
Overall dimensions from the Italvibras catalogue (A × C × B).
Documents to download
Documentation reserved for Audimat customers — request the access code.
Particularly suited to the following applications :
The CDX 10/22000-G houses a three-phase asynchronous motor whose enclosure applies the flameproof protection method « db »: the thickness of the frame and the geometry of the flameproof joints stop an internal explosion from spreading to the surrounding atmosphere. Protection IP66, impact resistance IK08, insulation class F (155 °C), continuous operation from −20 °C to +60 °C.
Note: unlike the G/D versions, type G CDX units have neither thermal protection nor a PTC thermistor. Motor protection must therefore be provided by the installation. An anti-condensation preheating system of 26 W remains available on request, advisable below −20 °C ambient.
CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.
A question about sizing, zone classification or compatibility with your installation ? get in touch.