GOOD VIBRATION

Italvibras electric vibrator motor CDX 15/550-G/D

Supplied and delivered by Audimat, official Italvibras distributor : three-phase 4-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.

ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22

Motovibrateur électrique Italvibras CDX 15/550-G/D

AudimatAUDIMAT

Availability

Variable stockContact us
Made to orderItalvibras
Also available as a single-phase version100-130 V 60 Hz or 200-240 V 50 Hz — Please consult us for the capacitor values.

Request a quote →

The CDX 15/550-G/D at Audimat

At 5,42 kN and 1’500 rpm, the CDX 15/550-G/D occupies size 20 in the CDX range. Its high-strength aluminium alloy frame and flameproof joints let it work inside a potentially explosive atmosphere.

This reference is one of the few sizes in the range that also exists as a single-phase version. Audimat, official Italvibras distributor.

Technical data

Centrifugal force (100 %, 50 Hz) 5,42 kN
Centrifugal force (100 %, 60 Hz) 5,81 kN
Speed (50 Hz) 1’500 rpm
Static moment (50 Hz) 219 kgmm
Rated power (50 Hz) 215 W
Max. power input (50 Hz) 300 W
Max. current (400 V / 50 Hz) 0,60 A
Weight 22,8 kg
Dimensions L×W×H 392 × 167 × 218 mm
Frame size 20
Cable gland NPT 1/2″, no cable gland
ATEX certification II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db
Permitted zones 1, 2, 21 and 22
Insulation class F (155 °C)
Protection IP66 — IK08
Item code 601411
Brand Italvibras

Overall dimensions from the Italvibras catalogue (A × C × B).

Documents to download

PDFCDX 4 pole datasheet

Documentation reserved for Audimat customers — request the access code.

Applications of the CDX 15/550-G/D

Particularly suited to the following applications :

Design and operation

The CDX 15/550-G/D is built around a three-phase asynchronous motor whose protection does not seek to prevent the internal explosion but to contain it. That is the principle of the « db » method, and it requires the enclosure and its joints to remain intact. Protection IP66, IK08, insulation class F (155 °C), permitted ambient from −20 °C to +40 °C, continuous duty S1.

The eccentric weights are set the same way round at both ends of the shaft and must read the same value on the graduated scale. The patented ARS device rules out any error of direction. Thermal protection 130 °C is fitted as standard.

CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.

A question about sizing, zone classification or compatibility with your installation ? get in touch.