Supplied and delivered by Audimat, official Italvibras distributor : three-phase 2-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.
ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22
Availability
The CDX 3/3200-G/D combines a speed of 3’000 rpm with a centrifugal force of 33,9 kN on 50 Hz. Frame size 70, in spheroidal graphite cast iron, designed for the flameproof protection method.
Its alloy steel shaft with isothermal hardening is sized for the repeated loading that vibratory work involves. Audimat, official Italvibras distributor.
| Centrifugal force (100 %, 50 Hz) | 33,9 kN |
| Centrifugal force (100 %, 60 Hz) | 30,5 kN |
| Speed (50 Hz) | 3’000 rpm |
| Static moment (50 Hz) | 344 kgmm |
| Rated power (50 Hz) | 2570 W |
| Max. power input (50 Hz) | 3100 W |
| Max. current (400 V / 50 Hz) | 5,23 A |
| Weight | 114 kg |
| Dimensions L×W×H | 594 × 325 × 343 mm |
| Frame size | 70 |
| Cable gland | NPT 3/4″, no cable gland |
| ATEX certification | II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db |
| Permitted zones | 1, 2, 21 and 22 |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Item code | 600323 |
| Brand | Italvibras |
Overall dimensions from the Italvibras catalogue (A × C × B).
Documents to download
Documentation reserved for Audimat customers — request the access code.
Particularly suited to the following applications :
The CDX 3/3200-G/D houses a three-phase asynchronous motor housed in a flameproof enclosure of type « db ». Gases from an internal explosion can only escape through flameproof joints whose geometry cools them before they reach the outside. Protection IP66, IK08, insulation class F (155 °C), permitted ambient from −20 °C to +40 °C.
The eccentric weights are set the same way round at both ends of the shaft and must read the same value on the graduated scale. The patented ARS device rules out any error of direction. Thermal protection 130 °C is fitted as standard.
CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.
A question about sizing, zone classification or compatibility with your installation ? get in touch.