Supplied and delivered by Audimat, official Italvibras distributor : three-phase 2-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.
ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22
Availability
The CDX 3/800-G/D is the 2-pole size 30 unit of the Italvibras flameproof series. At 3’000 rpm it delivers 7,35 kN on 50 Hz, with a high-strength aluminium alloy frame and an extra-thick terminal box cover sized to contain an internal explosion.
It is one of the few sizes in the range that also exists as a single-phase version. Audimat supplies and delivers it as official Italvibras distributor.
| Centrifugal force (100 %, 50 Hz) | 7,35 kN |
| Centrifugal force (100 %, 60 Hz) | 7,94 kN |
| Speed (50 Hz) | 3’000 rpm |
| Static moment (50 Hz) | 74,5 kgmm |
| Rated power (50 Hz) | 500 W |
| Max. power input (50 Hz) | 650 W |
| Max. current (400 V / 50 Hz) | 1,10 A |
| Weight | 23,3 kg |
| Dimensions L×W×H | 314 × 205 × 231 mm |
| Frame size | 30 |
| Cable gland | NPT 1/2″, no cable gland |
| ATEX certification | II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db |
| Permitted zones | 1, 2, 21 and 22 |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Item code | 600387 |
| Brand | Italvibras |
Overall dimensions from the Italvibras catalogue (A × C × B).
Documents to download
Documentation reserved for Audimat customers — request the access code.
Particularly suited to the following applications :
The CDX 3/800-G/D houses a three-phase asynchronous motor whose enclosure applies the flameproof protection method « db »: the thickness of the frame and the geometry of the flameproof joints stop an internal explosion from spreading to the surrounding atmosphere. Protection IP66, impact resistance IK08, insulation class F (155 °C), continuous operation from −20 °C to +40 °C.
Its centrifugal force adjusts steplessly from 0 to 100 % through the eccentric weights, with the patented ARS system preventing setting errors. Thermal protection 130 °C is fitted as standard, as on every type G/D CDX, and connecting it is an integral part of the conditions of use in a classified zone.
CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.