Supplied and delivered by Audimat, official Italvibras distributor : 4-pole vertical vibrator with a centre flange, increased safety, certified for gas and dust atmospheres.
ATEX CERTIFIED — GAS 1/2 & DUST 21/22
Availability
The MVB 1510/15-E-FLC is the increased safety version of the MVB-FLC. The same mechanical performance — 14,7 kN for 41,5 kg — but with certification covering gas atmospheres as well as dust.
It is the only way to equip a circular sieve in zone 1 or 2 in this format. Audimat, official Italvibras distributor.
| Centrifugal force | 14,7 kN — 1500 kgf |
| Poles | 4 poles |
| Speed | 1’500 / 1’800 rpm |
| Weight (without weights) | 41,5 kg |
| Mounting | Centre flange |
| ATEX certification | II 2 G — Ex e IIC T3 or T4 GbII 2 D — Ex tb IIIC T150 °C Db |
| Permitted zones | 1 and 2 (gas), 21 and 22 (dust) |
| Gas temperature class | T3 or T4 |
| Dust surface temperature | 150 °C |
| Thermal protection | On request, PTC thermistor 130 °C |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Ambient temperature | −20 to +40 °C, +55 °C on request |
| Overall height | 476 mm |
| Item code | 6E1225 |
| Brand | Italvibras |
| Class | Input | Rated | 400 V | tE | Ia/In |
|---|---|---|---|---|---|
| T3 | 1100 W | 730 W | 1,90 A | 9 s | 4,95 |
| T4 | 630 W | 480 W | 1,33 A | 5,5 s | 7,00 |
The gas temperature class is stated when ordering and fixes both the available power and the tE time for overload protection.
Documents to download
The MVB 1510/15-E-FLC houses a three-phase asynchronous motor with 4 poles, supplied from 220 to 690 V. Frame and end shields in spheroidal graphite cast iron, alloy steel shaft with isothermal hardening, bearings of specific geometry taking radial and axial loads. Protection IP66, impact resistance IK08, insulation class F, tropicalised as standard, continuous duty S1 from −20 to +40 °C.
PWM inverter control is available from 20 Hz up to base frequency, at constant torque, only where a correctly connected PTC thermistor is fitted. The catalogue also states that the components involved in the protection are checked and recorded at 100 %.
See the whole MVB-E-FLC range, the standard version MVB-FLC, or get in touch.