GOOD VIBRATION

Italvibras electric vibrator motor CDX 10/22000-G

Supplied and delivered by Audimat, official Italvibras distributor : three-phase 6-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas atmospheres.

ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1 & 2

Motovibrateur électrique Italvibras CDX 10/22000-G

AudimatAUDIMAT

Availability

Variable stockContact us
Made to orderItalvibras

Request a quote →

The CDX 10/22000-G at Audimat

The CDX 10/22000-G is size 110 of the Italvibras flameproof series in 6 poles. At 1’000 rpm it delivers 220 kN on 50 Hz, with a spheroidal graphite cast iron frame and an extra-thick terminal box cover sized to contain an internal explosion.

This is the largest frame in the series, a machine of over a tonne reserved for the heaviest structures. Audimat, official Italvibras distributor.

Technical data

Centrifugal force (100 %, 50 Hz) 220 kN
Centrifugal force (100 %, 60 Hz) 198 kN
Speed (50 Hz) 1’000 rpm
Static moment (50 Hz) 20025 kgmm
Rated power (50 Hz) 11800 W
Max. power input (50 Hz) 15600 W
Max. current (400 V / 50 Hz) 25,2 A
Weight 928 kg
Dimensions L×W×H 1150 × 610 × 614 mm
Frame size 110
Cable gland NPT 1″, no cable gland
ATEX certification II 2 G Ex db IIB 160 °C Gb
Permitted zones 1 and 2 (gas atmospheres)
Insulation class F (155 °C)
Protection IP66 — IK08
Item code 602201
Brand Italvibras

Overall dimensions from the Italvibras catalogue (A × C × B).

Documents to download

PDFCDX 6 pole datasheet

Documentation reserved for Audimat customers — request the access code.

Applications of the CDX 10/22000-G

Particularly suited to the following applications :

Design and operation

The CDX 10/22000-G houses a three-phase asynchronous motor whose enclosure applies the flameproof protection method « db »: the thickness of the frame and the geometry of the flameproof joints stop an internal explosion from spreading to the surrounding atmosphere. Protection IP66, impact resistance IK08, insulation class F (155 °C), continuous operation from −20 °C to +60 °C.

Note: unlike the G/D versions, type G CDX units have neither thermal protection nor a PTC thermistor. Motor protection must therefore be provided by the installation. An anti-condensation preheating system of 26 W remains available on request, advisable below −20 °C ambient.

CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.