GOOD VIBRATION

Italvibras electric vibrator motor CDX 10/2610-G/D

Supplied and delivered by Audimat, official Italvibras distributor : three-phase 6-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.

ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22

Motovibrateur électrique Italvibras CDX 10/2610-G/D

AudimatAUDIMAT

Availability

Variable stockContact us
Made to orderItalvibras

Request a quote →

The CDX 10/2610-G/D at Audimat

At 25,5 kN and 1’000 rpm, the CDX 10/2610-G/D sits at the top of the 6-pole series. Its size 70 and 150 kg suit it to heavy structures, where the low speed limits fatigue stress while still delivering a high force.

Its spheroidal graphite cast iron frame and bearing flange transmit the load evenly. Audimat supplies and delivers it as official Italvibras distributor.

Technical data

Centrifugal force (100 %, 50 Hz) 25,5 kN
Centrifugal force (100 %, 60 Hz) 26,9 kN
Speed (50 Hz) 1’000 rpm
Static moment (50 Hz) 2326 kgmm
Rated power (50 Hz) 1470 W
Max. power input (50 Hz) 1725 W
Max. current (400 V / 50 Hz) 3,80 A
Weight 150 kg
Dimensions L×W×H 676 × 325 × 343 mm
Frame size 70
Cable gland NPT 3/4″, no cable gland
ATEX certification II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db
Permitted zones 1, 2, 21 and 22
Insulation class F (155 °C)
Protection IP66 — IK08
Item code 602280
Brand Italvibras

Overall dimensions from the Italvibras catalogue (A × C × B).

Documents to download

PDFCDX 6 pole datasheet

Documentation reserved for Audimat customers — request the access code.

Applications of the CDX 10/2610-G/D

Particularly suited to the following applications :

Design and operation

The CDX 10/2610-G/D houses a three-phase asynchronous motor in a flameproof enclosure of type « db », whose integrity is what keeps the certification valid. Protection IP66, IK08, insulation class F (155 °C), permitted ambient from −20 °C to +40 °C, continuous duty S1.

From size 40 upwards, relubrication is through two greasing channels closed by screw plugs. These plugs must be refitted during operation without fail: leaving them open is a hazard in the event of an explosion. Quantities and intervals are given on the datasheet for the reference.

CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.

A question about sizing, zone classification or compatibility with your installation ? get in touch.