GOOD VIBRATION

Italvibras electric vibrator motor CDX 10/310-G/D

Supplied and delivered by Audimat, official Italvibras distributor : three-phase 6-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.

ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22

Motovibrateur électrique Italvibras CDX 10/310-G/D

AudimatAUDIMAT

Availability

Variable stockContact us
Made to orderItalvibras

Request a quote →

The CDX 10/310-G/D at Audimat

Size 30 of the CDX series, the CDX 10/310-G/D develops 3,15 kN at 1’000 rpm. Its high-strength aluminium alloy enclosure is sized so that the gases of an internal explosion cannot reach the surrounding atmosphere.

Its threaded cable entry takes a certified cable gland, to be fitted by the installer. Audimat, official Italvibras distributor.

Technical data

Centrifugal force (100 %, 50 Hz) 3,15 kN
Centrifugal force (100 %, 60 Hz) 3,32 kN
Speed (50 Hz) 1’000 rpm
Static moment (50 Hz) 286 kgmm
Rated power (50 Hz) 220 W
Max. power input (50 Hz) 350 W
Max. current (400 V / 50 Hz) 0,72 A
Weight 30,3 kg
Dimensions L×W×H 394 × 205 × 231 mm
Frame size 30
Cable gland NPT 1/2″, no cable gland
ATEX certification II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db
Permitted zones 1, 2, 21 and 22
Insulation class F (155 °C)
Protection IP66 — IK08
Item code 602318
Brand Italvibras

Overall dimensions from the Italvibras catalogue (A × C × B).

Documents to download

PDFCDX 6 pole datasheet

Documentation reserved for Audimat customers — request the access code.

Applications of the CDX 10/310-G/D

Particularly suited to the following applications :

Design and operation

The CDX 10/310-G/D is built around a three-phase asynchronous motor whose protection does not seek to prevent the internal explosion but to contain it. That is the principle of the « db » method, and it requires the enclosure and its joints to remain intact. Protection IP66, IK08, insulation class F (155 °C), permitted ambient from −20 °C to +40 °C, continuous duty S1.

The eccentric weights are set the same way round at both ends of the shaft and must read the same value on the graduated scale. The patented ARS device rules out any error of direction. Thermal protection 130 °C is fitted as standard.

CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.

A question about sizing, zone classification or compatibility with your installation ? get in touch.