Supplied and delivered by Audimat, official Italvibras distributor : three-phase 2-pole foot-mounted electric vibrator motor with a flameproof enclosure, certified for gas and dust atmospheres.
ATEX CERTIFIED — FLAMEPROOF ENCLOSURE — ZONES 1/2 & 21/22
Availability
The CDX 3/2100-G/D is size 50 of the Italvibras flameproof series in 2 poles. At 3’000 rpm it delivers 20,7 kN on 50 Hz, with a spheroidal graphite cast iron frame and an extra-thick terminal box cover sized to contain an internal explosion.
Its spheroidal graphite cast iron frame and bearing flange spread the load evenly into the structure. Audimat, official Italvibras distributor.
| Centrifugal force (100 %, 50 Hz) | 20,7 kN |
| Centrifugal force (100 %, 60 Hz) | 20,4 kN |
| Speed (50 Hz) | 3’000 rpm |
| Static moment (50 Hz) | 209 kgmm |
| Rated power (50 Hz) | 900 W |
| Max. power input (50 Hz) | 1000 W |
| Max. current (400 V / 50 Hz) | 1,71 A |
| Weight | 59,8 kg |
| Dimensions L×W×H | 520 × 235 × 279 mm |
| Frame size | 50 |
| Cable gland | NPT 3/4″, no cable gland |
| ATEX certification | II 2 G Ex db IIB 120 °C GbII 2 D Ex tb IIIC T120 °C Db |
| Permitted zones | 1, 2, 21 and 22 |
| Insulation class | F (155 °C) |
| Protection | IP66 — IK08 |
| Item code | 600317 |
| Brand | Italvibras |
Overall dimensions from the Italvibras catalogue (A × C × B).
Documents to download
Documentation reserved for Audimat customers — request the access code.
Particularly suited to the following applications :
The CDX 3/2100-G/D is built around a three-phase asynchronous motor whose protection does not seek to prevent the internal explosion but to contain it. That is the principle of the « db » method, and it requires the enclosure and its joints to remain intact. Protection IP66, IK08, insulation class F (155 °C), permitted ambient from −20 °C to +40 °C, continuous duty S1.
The 130 °C thermal protection, fitted as standard on type G/D units, connects to a circuit rated for a maximum of 600 V a.c. and 720 VA, controlled by a pulse switch with manual reset. A PTC thermistor 130 °C is available on specific request.
CDX units ship without a cable gland : the user must fit one, certified for flameproof enclosures and compliant with the standards of the country of installation. Installation, wiring and maintenance of this series follow strict rules, set out in our guide to the CDX flameproof vibrator motor.
A question about sizing, zone classification or compatibility with your installation ? get in touch.